Viscometer is used to determine the viscosity of non-Newtonian fluids, e.g.most paints. Digital version with constant speed motor rotating at 200 r.p.m for greater accuracy and repeatability, and removing the need for separate weights used in order models. The quick release chuck enables rapid cleaning and changeover of the paddle and digital display gives the reading in Krebs units or grams. KU-2 kreb stormer viscometer uses multipoint calibration across the torque range and a remote calibration key allows the instrument to be secure from accidental adjustment. Magnetic base holds sample container in place. Complies with ASTM-D562
The quick release chuck enables rapid cleaning and changeover of the paddle and digital display gives the reading in Krebs units or grams.
KU-2 kreb stormer viscometer uses multipoint calibration across the torque range and a remote calibration key allows the instrument to be secure from accidental adjustment. Magnetic base holds sample container in place.Complies with ASTM-D562
|
Technical Parameters:
-
• Range:40.2KU~141.0KU 150-4000 mPa.S
-
• Accuracy:±1.5% of full scale range
-
• Repeatability:±1% of full scale range
-
• Paddle speed:200r/min±0.5r/min
|
|
Brookfield Dial Reading Viscometers |
Easy speed Adjustment and On/Off Control
It's improved with a multi-speed, electronic drive and ergonomically designed speed control knob. Quickly select any one of 10 pre-set speeds (8 speeds on LVT models).
This new direct-drive design means extremely quiet operation and greater versatility. The new Universal Power Supply facilitates the use of worldwide power sources.
|
Choose the right accessory for your application:
-
• Viscosity Standard Fluids
-
• TC Series Baths
-
• Small Sample Adapter
-
• Ultra Low Adapter for expanding lower range capability
|
Model |
Viscosity Range |
RPM(No. of increments) |
Spindles |
Min |
Max |
LVT |
1¹ |
2M |
0.3-60 rpm (8) |
4 |
RVT |
100² |
8M |
0.5-100 rpm (10) |
6 |
HAT |
200² |
16M |
0.5-100 rpm (10) |
6 |
HBT |
800² |
64M |
0.5-100 rpm (10) |
6 |
|
1 cP achieved with UL Adapter accessory. 15 cP on LV with standard spindles
Using spindles provided. Ranges can be expanded or reduced using accessories |
|
Brookfield Digital Reading Viscometers - DV-I Prime |
Features:
-
• Displayed info:
- Viscosity (cP or mPa•s)
- % Torque
- Speed/Spindle
- Temp (°C or °F) if optional RTD Temperature Probe is installed
-
• 18 speeds provide great range capability
-
• New Direct access to time measurement function (time to torque, time to stop)
-
• New Output connection to printer
-
• Displays under/over range conditions
-
• Auto Range Showing
- Full Scale Range (FSR) at 100%
- Maximum viscosity measured with Spindle/Speed combination
-
• Scroll Keys for Simple Selection of Speed & Spindle
-
• New Temperature off-set capability to ±5°C
-
• Accuracy: ±1.0% of range
-
• Repeatability: ±0.2%
|
Technical Specifications:
Model |
Viscosity Range
cP(mPa•s) |
RPM(No. of increments) |
Spindles |
Min |
Max |
LVDV-IP |
1* |
2M |
.3 -100 (18) |
4 |
RVDV-IP |
100 |
13M |
.3 -100 (18) |
6 |
HADV-IP |
200 |
26M |
.3 -100 (18) |
6 |
HBDV-IP |
800 |
104M |
.3 -100 (18) |
6 |
|