Coating Thickness Meter
ISO 2808. Determination of film thickness
ISO 2178. Measurement of coating thickness -Magnetic method
ISO 2360. Measurement of coating thickness – Amplitude- sensitive eddy-current method
The Paint Test Equipment Coating Thickness Meter easily measures all coatings on metallic substrates using the magnetic induction or eddy current principles, ensuring the correct coating thickness has been applied.
One of the most advanced Coating Thickness Meters on the market, using up-to-date technology in a robust portable instrument, incorporating all the following user functions through a menu-driven back-lit display.
Calibration : Calibrate on any blasted profile or shape of substrate using the Calibration Foils supplied.
Calibration Memories : The calibration settings for different substrates and shapes can be stored and recalled when required, saving time on recalibration.
Statistics : Continually shows Mean, Number of Readings, Max/Min, Coefficient of Variation and Standard Deviation.
Hi/Lo Limits : Pass and fail with audible and visual alarm.
Metric/Imperial : Select the measurement units that you require.
Batching : Measurements that are taken can be stored into batches which incorporate batch number, unique job number, and date and time. You can also go back to previous batches and look at the statistics and add or cancel readings from previous batches.
Probe Speed :Select a fast or slow reading speed when the probe is placed on the surface.
Complies with International Standards |
Ferrous Models |
Non-Ferrous Models |
ISO 2178 |
ISO 2360 |
ISO 2808-6 |
ISO 2808-6 |
ASTM B 499 |
ASTM D 1400 |
ASTM B 244 |
|
Eban 4000 Probe Specifications: |
Probe |
Probe Diameter |
Working Head-room |
Minimum Convex Radius |
Minimum Con-cave Radius |
Minimum Sample Area |
Ferrous Straight 0-1000μm |
9mm / 360mils |
75mm / 3” |
4mm / 160mils |
25mm / 1” |
4mm / 160mils |
Ferrous Right Angle 0–1000μm |
9mm / 360mils |
40mm / 1.5” |
4mm / 160mils |
25mm / 1” |
4mm / 160mils |
Ferrous Straight 0–2000μm / 0–5mm |
15mm / 600mils |
75mm / 3” |
10mm / 400mils |
50mm / 2” |
10mm / 400mils |
Ferrous Straight 0–20mm |
50mm / 2” |
150mm / 6” |
100mm / 4” |
500mm / 20” |
100mm / 4” |
Non-Ferrous Straight 0–1000μm |
10mm / 400mils |
75mm / 3” |
5mm / 200mils |
25mm / 1” |
5mm / 200mils |
Non-Ferrous Right Angle 0–1000μm |
10mm / 400mils |
40mm / 1.5” |
5mm / 200mils |
25mm / 1” |
5mm / 200mils |
Non-Ferrous Straight 0–2000μm |
10mm / 400mils |
75mm / 3” |
5mm / 200mils |
25mm / 1” |
5mm / 200mils |
Coating Thickness Meter Specifications: |
Part No |
Substrate |
Range Metric |
Range Imperial |
Resolution |
Accuracy |
Cal Cert
Part No |
Foil Cert
Part No |
Metric |
Imperial |
C5001 |
Ferrous |
0–1000μm |
0–40mils |
1um |
0.1 mil |
±1 to 3% |
NC101 |
NC002 |
C5002 |
Ferrous |
0–2000μm
0–5mm |
0–80mils
0–200mils |
1um 0.01mm |
0.1 mil |
±1 to 3% |
NC101 |
NC002 |
C5003 |
Ferrous |
1–20mm |
40–800mils |
0.1mm |
0.1 mil |
±1 to 3% |
NC101 |
NC002 |
C5004 |
Non-Ferrous |
0–1000μm |
0–40mils |
1um |
0.1 mil |
±1 to 3% |
NC201 |
NC002 |
C5005 |
Non-Ferrous |
0–2000μm |
0–80mils |
1um |
0.1 mil |
±1 to 3% |
NC201 |
NC002 |
C5006 |
Ferrous & Non-Ferrous |
0–1000μm |
0–40mils |
1um |
0.1 mil |
±1 to 3% |
NC101 NC201 |
NC002 |
C5007 |
Ferrous & Non-Ferrous |
F 0–2000μm
F 0–5mm
N 0–2000μm |
0–80mils
0–200mils
0–80mils |
1um 0.01mm 1um |
0.1 mil |
±1 to 3% |
NC101 NC201 |
NC002 |
CA101 |
USB computer download Cable |
|
|
CS301 |
Spare Ferrous Probe 0–1000μm (To fit Coating thickness Meter C5001 & C5006) |
NC101 |
|
CS302 |
Spare Ferrous Probe 0–2000μm & 0–5mm (To fit Coating thickness Meter C5002 & C5007) |
NC101 |
|
CS303 |
Spare Ferrous Probe 0–20mm (To fit Coating thickness Meter C5003) |
NC101 |
|
CS304 |
Spare Non-Ferrous Probe 0–1000μm (To fit Coating thickness Meter C5004 & C5006) |
NC201 |
|
CS305 |
Spare Non-Ferrous Probe 0–2000μm (To fit Coating thickness Meter C5005 & C5007) |
NC201 |
|
CA201 |
Ferrous Right Angle Probe 0–1000μm (To fit Coating thickness Meter C5001 & C5006) |
NC101 |
|
CA203 |
Non-Ferrous Right Angle Probe 0–1000μm (To fit Coating thickness Meter C5004 & C5006) |
NC201 |
|
Ferrous models will measure all non-ferromagnetic coatings on steel and iron.
Non-Ferrous models will measure all non-conductive, non-ferromagnetic coatings on conductive Non-Ferrous substrates.
All models are supplied in a Industrial Foam-Filled Carrying Case with flexible lead Measuring Probe (Ferrous and Non Ferrous instruments have two Measuring Probes), set of 8 Calibration Foils and Zero Disk (Ferrous and Non Ferrous instruments have two Zero Disks and C5003 Model as 3 Foils).
The USB Computer Download Cable is available as a optional extra.
Selecting instrument model for different coatings and substrates |
Coating |
Substrate |
Aluminium |
Brass |
Bronze |
Copper |
Magnesium |
Steel |
Stainless |
Titanium |
Zinc |
Aluminium |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Anodizing |
Non-Ferrous |
_ |
_ |
_ |
Non-Ferrous |
_ |
_ |
_ |
_ |
Brass |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Bronze |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Cadmium |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Ceramic |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Chrome |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Copper |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Eloxal |
Non-Ferrous |
_ |
_ |
_ |
_ |
_ |
_ |
_ |
_ |
Epoxy |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
_ |
Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Galvanizing |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Metal spray |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Lacquer |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
_ |
Ferrous |
Non-Ferrous |
_ |
Non-Ferrous |
Paint |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Plastic |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Ferrous |
Non-Ferrous |
Non-Ferrous |
Non-Ferrous |
Rubber |
Non-Ferrous |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Tin |
_ |
_ |
_ |
_ |
_ |
Ferrous |
_ |
_ |
_ |
Calibration Foils Specifications: |
Part No . |
Range |
Values |
Accuracy |
Foil Cert.
Part No |
F2001 |
0-1000um |
25, 50, 75, 125, 175, 250, 500, 750um |
±2% |
NC002 |
F2002 |
0-40mils |
1, 2, 3, 5, 7, 10, 20, 30mils |
±2% |
NC002 |
F2003 |
0-2000um |
50, 250, 500, 750, 1000, 1250, 1500, 2000um |
±2% |
NC002 |
F2004 |
0-80mils |
2, 10, 20, 30, 40, 50, 60, 80mils |
±2% |
NC002 |
F2005 |
0-5.00mm |
50, 250, 500, 750, 1000, 1500, 2000, 3000um |
±2% |
NC002 |
F2006 |
0-200mils |
2, 10, 20, 30, 40, 60, 80, 120mils |
±2% |
NC002 |
F2007 |
1-20.0mm |
5, 9.5, 15mm |
±2% |
NC002 |
F2008 |
1-800mils |
200, 360, 600mils |
±2% |
NC002 |
FV001 |
Special Range
Select 8 values |
12, 25, 50, 75, 100, 125, 150, 175, 190, 200, 225, 250, 275, 300, 350, 375, 500, 625, 750, 1000, 1250, 1500, 2000, 3000, 5000, 9500,15000um (also available in mils on request) |
±2% |
NC002 |
Z1003 |
Zero Disk Ferrous |
Z1004 |
Zero Disk Non-Ferrous |
Z1005 |
Zero Plate Ferrous (1-20mm Coating Thickness Meter) |